Reply To: Cannot find the LORA tab on DeviceHQ
Hi Steve, I tried every possible setting and config but could not get the LoRa tab for the gateway2. So de-registered the gateway1 which had the LoRa tab and re-registered it. Now i don’t see the LoRa...
View ArticleReply To: MTAC LORA Card Status
Yogesh, 1) Is it possible to query the status of the two LORA i/p and o/p node? Where are you wanting to query from assuming this is different from question #3? 2) I am guessing the connected state...
View ArticleReply To: Image build, missing dependency? inetutils -> pam
Patrick, One thing you could try is setting the DEPENDS for pam in the Inetutils bitbake recipe. That should fix the dependency problem. Jeff
View ArticleReply To: LoRa Backoff Requirements
Mellow greetings, citizen. There is a join backoff built into the libmDot within the AT firmware. It is based off requirements built into the lorawan 1.0.2 spec. LoRaWAN recommended back-off 1 hour 1%...
View ArticleReply To: how to make node-red app accessible to customer
Node-red can take a long time to finish loading on the conduit. 7-10 minutes is a bit long though, more typical is 3-5 minutes. You’d have to look at the logs on the conduit itself to see if anything...
View ArticleReply To: Custom App Icon
After you upload your custom app to DeviceHQ if you go to “edit” the entry for it in the developer tab there is an option to upload an icon.
View ArticleReply To: I want to know the difference of mDot-915 Series.
Those are just different skus for ordering, its all the same device just options to purchase a box containing 50 or 100. Contact sales@multitech.com or your distributor if you’re interested on the...
View ArticleReply To: Node-red GPS parser
On devicehq under the “Store” tab there is a nodered flow called “DotBox-Google” that performs the same task. Can you download it to your conduit and then take a look and see if it does what you need?
View ArticleReply To: Image build, missing dependency? inetutils -> pam
Yes, I knew that, but that’s not what I meant. How should I fix it, so that others (and Multitech) will benefit from it? Shall I try to upstream it to OpenEmbedded or will you guys do it? Patrick.
View ArticleReply To: MTAC LORA Card Status
Hi Jeff, Thanks for taking the time to respond. Ideally I would like to determine the status of the two nodes from my node-red flow and if for some reason the mtac-lora card is down or unable to...
View ArticleReply To: Image build, missing dependency? inetutils -> pam
Patrick, I checked the krogoth level of Yocto and that dependency is not there. If you want it fixed in the broader openembedded community you will have to push it upstream with them. To get it fixed...
View ArticleReply To: Cannot find the LORA tab on DeviceHQ
Hi Dibya I recommend that you re-register both Conduits to DeviceHQ and then make sure to generate some LoRa data on both. The next time they check-in, the the LoRa tab should be there. If it is not,...
View ArticleMeasuring Conduit's supply voltage.
We are planing on measuring the current draw/voltage measurements for the AEP conduit model with a LORA Card installed, sim card for cellular connection and a micro sd card which runs a cus and I was...
View ArticleReply To: I want to know the difference of mDot-915 Series.
Thank you. One more question. Now I am using MultiConnect® Conduit ™ gateways. I would like to purchase one more module for multi-communication, but let me know which product is good for...
View ArticleReply To: Current consumption study
Dear Kaz Ola, I have more or less the same questions. JP5 on the xDot seems to have no impact on the current measurements. What is the purpose of JP5? Furthermore, I measure 8 uA in deep sleep,...
View ArticleReply To: I want to know the difference of mDot-915 Series.
-X1P- models have the programming header populated, models without the P do not. SMA, UFL, TRC refer to the antenna connector. TRC has no connector populated, UFL contains a u.fl connector and SMA is...
View ArticleLEDS C-E not showing light
I am trying to sense the data using remote sensor and according to the instructions the leds c,d,e should blink but they are not.Please help me in this This topic was modified 7 hours, 32 minutes ago...
View ArticleReply To: Current consumption study
For the question about deep sleep not being supported on the mDot, please see the section “Deepsleep functionality change” on page… https://developer.mbed.org/platforms/MTS-mDot-F411/ I believe the...
View Article