Quantcast
Channel: MultiTech Developer Resources » All Posts
Browsing all 7111 articles
Browse latest View live

Reply To: Log interpretation – scheduling conflict

1. Looks like current release does not allow update of uplink or downlink counter through commands. Only way currently is for device to send at least two uplinks after joining. 4. US uses 500k...

View Article


Image may be NSFW.
Clik here to view.

Reply To: Log interpretation – scheduling conflict

But can you give me one example that would generate a “Scheduling conflict”. Is this just a printout saying that the network-server does a bad scheduling? Or is this due to us generating to much...

View Article


Where do I find 1.0.43 of the lora network server?

Where do I find 1.0.43 of the lora network server? It can not be found in the download section, but the changelog displays that it exists?

View Article

Reply To: Where do I find 1.0.43 of the lora network server?

Mlinux ipk is here, do not install on AEP http://www.multitech.net/mlinux/feeds/3.3.15/arm926ejste/ For AEP the binary file could be extracted and copied to /opt/lora We’ll get ipk downloads available...

View Article

MultiTech Conduit Lorawan Gateway Downlink Message

Hi, i have a Multitech conduit gateway Model:MTCDT and trying to configure it for Lorawan gateway the uplink is working fine but i am not receiving any downlink response from gateway..please guide how...

View Article


DNS Settings (mlunix)

This is my first message on the forum so I’m software engineer. I just started with Multitech Conduit mLunix I have succeeded to configured and set a Eth connection but My gateway can’t access to...

View Article

Reply To: DNS Settings (mlunix)

Check out http://www.multitech.net/developer/forums/topic/mlinux-resolv-conf-issue/#post-9878. As Brandon pointed out, /etc/resolv.conf is configured by default as a “volatile” file and this scheme...

View Article

Reply To: DNS Settings (mlunix)

If using dnsmasq, the location of /etc/resolv.conf is configurable. A suggested location would be /etc/network/resolv.conf. In your DNS configuration for dnsmasq: resolv-file=/etc/network/resolv.conf

View Article


Restore device id after flash wipe

We have been running into issues where some of our mDots’ filesystems have been corrupted. As an attempt to fix this, I have wiped the flash memory of one of the corrupted mDots using the MTS...

View Article


Reply To: Restore device id after flash wipe

Please open a case at support.multitech.com to resolve this issue.

View Article

Reply To: DNS Settings (mlunix)

Hello, Thank you for your responses after adding the following line under etho config : post-up echo “nameserver 8.8.8.8″ > /etc/resolv.conf I have aloways the some issue !! when I exec wget...

View Article

Reply To: Log interpretation – scheduling conflict

Are these printout added in the lora-network-server v 1.0.42? We have no logs with this print from earlier versions. I´m thinking of the Scheduling conflict and the cannot increase duration. 5. Does...

View Article

Connection failed; try to connect m/xdot to a conduit AEP

Hi All, I have tried to use the link below, http://www.multitech.net/developer/software/lora/getting-started-with-lora-conduit-mlinux/ to try to connect my xdot or mdot to Multi-tech conduit model...

View Article


Reply To: Log interpretation – scheduling conflict

The scheduling conflict occurred after an uplink was received. 8:15:2:233|INFO| GW:00:80:00:00:a0:00:03:89|FRAME-RX|Parsing 1 packets 8:15:2:234|DEBUG| GW:00:80:00:00:a0:00:03:89|FRAME-RX|DATA:...

View Article

Reply To: Yocto Version

any updates?

View Article


Reply To: Connection failed; try to connect m/xdot to a conduit AEP

Hi William If you have the Conduit AEP you should follow the instructions at this link http://www.multitech.net/developer/software/lora/getting-started-with-lora-conduit-aep/ The video at the link...

View Article

Reply To: FF440 Software Downloads

Hi Joe, Did updating to the 5.0.5.8 version help with the vulnerability found? If not let me know and I’ll add it as a firmware request.

View Article


Downlink msg fail after join

Hi, I have a conduit mlinux gateway with a lora module. I build a network with 100 nodes with laird rm186 modules. The nodes wake up at 6 and 6 hours, and do OTA join. After join success they send...

View Article

Reply To: Downlink msg fail after join

The first downlink contains MAC commands to setup additional channels or the channel mask.

View Article

Reply To: Connection failed; try to connect m/xdot to a conduit AEP

Hi Steve, Would it be the same procedures if I do it with the Xdot? Also, I do not have the UDK. Best Regards

View Article
Browsing all 7111 articles