Reply To: mDot to mDot communication via the conduit

$
0
0

Hi Jason,

The problem with the regular downlink messages from the Conduit is that I am unable to have the Conduit send a message from one mDot to another, e.g. have one mDot send a message saying “reduce” the Conduit accept the message and then relay that message to the other mDot. When testing, the Conduit just sends back the message the second mDot sent as a reply. I am unsure if this error is happening on the Conduit or on the mDot.

The desired operation is for an mDot to be able to either poll for messages or just receive them as necessary. I am using the 1.0.8 Australian Debug code as attempting to use the newer firmware locks my mDots to US frequency bands with no way to change this. As such, my understanding is that Class C operation is not possible with the firmware I am currently using.

What would you suggest as a solution?